某列管换热器,用100℃水蒸气将物料由20℃加热至80 ℃,传热系数K=100 W/(m2 .℃).经半年运转后,由于污
来源:学生作业帮 编辑:拍题作业网作业帮 分类:数学作业 时间:2024/04/27 17:02:36
某列管换热器,用100℃水蒸气将物料由20℃加热至80 ℃,传热系数K=100 W/(m2 .℃).经半年运转后,由于污
垢的影响,在相同条件下物料出口温度仅为70℃.现欲使物料出口温度仍维持在80℃,问加热蒸气温度应取何值?
原qc(80-20)=KAΔ t 1 (1)
Δ t =(80-20)/ln(80/20)=43.28℃
半年后qc(70-20)=K AΔ t 2 (2)
Δ t= 80-30/ln(80/30)=50.98℃
2/1得
70-20/80-20=K Δ t 1/KΔ t2
(K /100)×50.98/43.28
K =70.75 w.m .K
保持原生产能力,即 KAΔ t K AΔ t (2’)
Δ t =KΔ t /K =100×43.28/70.75
=61.17℃ (3’)
Δ t =(T-20)-(T-80)/ln(T-20)/(T-80)
=61.17
∴ 60/61.17ln(T-20)/(T-80)
∴2.667=T-20/T-80
T=115.8℃
垢的影响,在相同条件下物料出口温度仅为70℃.现欲使物料出口温度仍维持在80℃,问加热蒸气温度应取何值?
原qc(80-20)=KAΔ t 1 (1)
Δ t =(80-20)/ln(80/20)=43.28℃
半年后qc(70-20)=K AΔ t 2 (2)
Δ t= 80-30/ln(80/30)=50.98℃
2/1得
70-20/80-20=K Δ t 1/KΔ t2
(K /100)×50.98/43.28
K =70.75 w.m .K
保持原生产能力,即 KAΔ t K AΔ t (2’)
Δ t =KΔ t /K =100×43.28/70.75
=61.17℃ (3’)
Δ t =(T-20)-(T-80)/ln(T-20)/(T-80)
=61.17
∴ 60/61.17ln(T-20)/(T-80)
∴2.667=T-20/T-80
T=115.8℃
根据饱和蒸汽 压力与温度对照表 试着选两个看看 哪个能达到要求
某列管换热器,用100℃水蒸气将物料由20℃加热至80 ℃,传热系数K=100 W/(m2 .℃).经半年运转后,由于污
化工原理题目某列管,用110度的蒸汽把物料由25度加热到85度,传热系数110,一年后由于污后的影响,相同操作条件下,物
列管式换热器计算问题用水蒸气加热蒸馏水,水流量是75t/h,进入温度是20℃,出口温度为85℃.进口饱和水蒸汽压强为60
一个夹套换热器,130℃的饱和水蒸气通入其中,物料在100℃的条件下蒸煮30分钟,物料出来的温度怎么算?
一道化工原理题.有一传热面积为3m2,由φ25x2.5mm的管子组成的单程列管式换热器,用初温为10℃的水将机油由200
某单壳程单管程列管换热器,壳程为水蒸气冷凝,蒸汽温度T为140度,管程为空气,空气由20度被加热到90度,现将此换热器由
列管式换热器,用水蒸气加热液体,水蒸气走管程还是壳程
水蒸气加热苯列管式换热器的设计
260°C和334°C时水蒸气的传热系数?列管换热器
在列管式换热器中用冷水将90℃的热水冷却至70℃.热水走管外,单程流动,流量为2.0kg/s.冷水走管内,...
一题化工原理-传热.有一列管式换热器,换热面积40m2,列管为φ25X2.2mm.用饱和水蒸气将处理量为25000KG/
列管换热器中汽水换热时传热系数K是取值还是计算 如果取值怎么取 如果计算怎么计算