英语翻译sensor sensitivity [mV/EU] specifies the sensitivity of

来源:学生作业帮 编辑:拍题作业网作业帮 分类:综合作业 时间:2024/05/09 09:56:32
英语翻译
sensor sensitivity [mV/EU] specifies the sensitivity of the sensor in mV/EU.The default is 1000.00.​engineering units specifies the engineering units.The default is V.If you are using a microphone,select Pa.If you are using an accelerometer,select g,m/s^2,or in/s^2.If the units you need are not listed,select custom and enter the unit to use in custom label.​dB reference [EU] specifies the reference value to use when you compute the results in decibels and when you scale a signal to engineering units.dB reference [EU] uses the unit that you specify in engineering units.The default is 1.When engineering units is V,use a dB reference [EU] of 1.When engineering units is m,use a dB reference [EU] of 0.7746.When engineering units is Pa,use a dB reference [EU] of 20E–6.​custom label specifies the string used for units when engineering units is set to custom.If engineering units is not set to custom,this parameter is ignored.The default is EU.​weighting filter specifies if any weighting filter has been applied to the signal.This control does not apply any weighting to the signal.weighting filter must always return linear for calibration measurements.The default is linear.Use weighting filter only if the acquired signal has been weighted by an external device before it is acquired by a DAQ device.If a weighting filter was applied to the signal before reaching the DAQ device,using weighting filter prevents subsequent VIs from applying any additional weighting to the weighted signal.​pregain [dB] specifies the pregain applied by an external amplifier expressed in decibels.A value of 0 dB specifies no pregain.The default is 0.00 dB.Use pregain [dB] only if an external device amplifies the signal before a DAQ device acquires the signal.If you apply any gain with the DAQ device itself,the driver software takes this into account and you do not need to enter the information.
输出电压传感器的灵敏度[mV/欧盟指定的灵敏度的传感器,以mV /欧盟.默认值是1000.00.工程单位指定的工程单位.默认值是五,如果您使用的是选择G,M /s ^ 2/s ^ 2的加速度计,如果您使用的是麦克风,选择宾夕法尼亚州.如果您需要的单位没有列出,请选择“自定义”,然后输入单位使用自定义标签.dB参考[EU]时要使用的分贝数和计算的结果,当您调整信号工程单位指定的参考价值.dB参考[EU]采用单元中指定的工程单位.默认值是1.当工程单位是V,使用dB参考[EU]1.当工程单位为m,使用DB参考文献[欧盟]0.7746.当工程单位是Pa,使用DB参考文献[欧盟]20E-6.自定义标签指定单位工程单位设置为自定义时,使用的字符串.如果工程单位设置为自定义时,此参数将被忽略.默认值是欧盟.加权滤波器指定如果任何加权滤波器已被施加到信号.这种控制并不适用于任何加权的信号.加权滤波器必须返回线性校准测量.在默认情况下是线性的.只有当采集的信号通过一个外部设备进行加权,被收购前的数据采集设备,使用加权滤波器.如果一个加权滤波器被施加到信号到达DAQ设备之前,使用加权滤波器可以防止后续的从施加任何额外的加权的加权信号的VI.pregain[dB]的应用由外部放大器,以分贝表示指定的pregain的.0分贝值指定没有pregain的.默认值是0.00分贝.使用pregain[DB]只有当外部设备的信号进行放大前的数据采集设备获取的信号.如果你申请的任何收益与DAQ设备本身,驱动程序软件需要考虑到这一点,你并不需要输入的信息.